EME-MOTIONAL OPTICSCONNECTIVITY & PHOTONICS Request a Quote

Classification Code of Lighting Distribution Boxes

Lighting distribution boxes are classified under the Uniclass code Pr_60_70_22, which standardizes their identification in construction and electrical design.

Uniclass Classification

Lighting distribution boxes, along with other switchboards and electrical distribution equipment, are categorized in the Uniclass system under the code Pr_60_70_22 . This code is part of the latest Uniclass Products table (v1.42, April 2026) and is used to standardize product identification for construction projects, ensuring consistency in documentation, procurement, and design workflows. Uniclass codes are widely adopted in the UK and internationally for BIM (Building Information Modeling) and project management.

Electrical and Lighting Standards

Distribution boxes are also referenced in Division 26 of construction standards, which covers electrical and lighting systems, including power distribution, switchboards, and on-site generation . These standards ensure that lighting distribution boxes meet safety, performance, and installation requirements.

Luminaire and Light Distribution Classification

While the Uniclass code identifies the physical distribution box, the light distribution inside the box is classified according to standards such as EN 13032-2 and CIE 040-1978 . These standards define parameters for luminous flux distribution, including:

  • Direct and indirect light ratios
  • Luminous flux fractions in solid angle ranges
  • Upward flux fraction (UFF) This classification helps designers understand how light is distributed from luminaires connected to the distribution box, ensuring efficient illumination for indoor or outdoor applications.

Practical Implications

  • Design and Procurement: Using the Uniclass code Pr_60_70_22 allows architects and engineers to specify the correct type of distribution box in project documentation.
  • Compliance: Ensures adherence to electrical safety and lighting standards.
  • Integration with BIM: Facilitates digital modeling and coordination of lighting systems in construction projects. In summary, lighting distribution boxes are primarily classified under Uniclass Pr_60_70_22, while the light output and distribution from connected luminaires are further classified using EN 13032-2 and CIE 040-1978 standards to ensure proper illumination and compliance with design requirements .
Classification Code of Lighting Distribution Boxes - E-Motional Optics & Connectivity

IESNA lighting distribution types and their applications | ZGSM

Illuminating Engineering Society of North America (IESNA) is an organization dedicated to research and standards development for

What is the difference between lighting distribution box and power

Lighting distribution circuit breakers are generally of distribution type and lighting type (medium and small short-time overload times).

Classification of Lighting Fixtures and Main Related Standards

1.2 Classification by Photometric Distribution The most common classification method used by lighting designers is probably the one

Classification of Explosion-proof Lighting Distribution Boxes

Overview Explosion proof lighting follows two main systems: the North American Class/Division system and the international Zone

Pr_60_70_22 Distribution boxes and switchboards | Uniclass

Browse the full set of Uniclass tables, delivered, managed and maintained by NBS.

Main technical conditions of lighting distribution box

The lighting distribution box is a device used to supply power and control the lighting system, and its main technical conditions

Understanding Power Distribution Boxes: Types, Features, and

This guide delves into the intricacies of power distribution boxes, shedding light on their design, functionality, and

Light distribution categories

Light distribution categories Categorizing of luminaires due to their light distribution: Light distributions of luminaires are categorized

Lighting Distribution Systems: Flex Connectors & More

Lighting Distribution Systems Looking to power up your Lighting, Lamps & Tubes projects? Our comprehensive range of Lighting

What Is IES Light Distribution Type I, Type II, Type III, Type IV, Type V?

The IES establishes and maintains the standards for light distribution types, which are widely used and referenced by

Lighting Distribution Board — IEC 61439-3 (DBO) Compliance

Lighting Distribution Board assemblies intended for operation by ordinary persons fall under IEC 61439-3, which covers Distribution

Distributing light safely

Distributing light safely - everything about the distribution fuse box for lighting Reliable lighting does not start with the lamp, but with

What Is a Distribution Box? Types, Components & How

A distribution box, also called an electrical distribution box, distributes incoming power to

What Are Light Distribution Types Defined By IESNA and NEMA?

IESNA LED Light Distribution Types have two classification systems. One has been established by the Illumination

Hazardous Area Lighting Classifications: Definitions

When lighting is in one of these hazardous locations, technically an area at risk of fire or explosion, the U.S. National

What Is Light Distribution Type I, II, III, IV & V?

Choosing the right light distribution is critical to having good lighting. This article will help you know the different types

1910.307

Division and zone classification. In Class I locations, an installation must be classified as using the division classification system

Hazardous Location Lighting: NEC Class I, II & III Guide

The National Electrical Code (NEC) and National Fire Protection Association (NFPA) divide hazardous locations into three broad

What are the light distribution types of T1, T2, T3, T4, and T5 defined

The IESNA-defined light distribution types (T1, T2, T3, T4, and T5) provide a universal framework for designing

NEMA Enclosure Types

Comparison Between NEMA Enclosure Type Numbers and IEC Enclosure Classification Designations IEC Publication 60529

Light distribution categories

The selected LDC-class influences the room utilization factor: as wider the distribution, as darker the room and as lower the direct

Lighting Distribution Box: Safety, Efficiency, and Convenience in

Discover the essential functions and benefits of the lighting distribution box for optimized electrical lighting. Enhance safety, save on

2017 Code digest

Foreword Eaton''s Crouse-Hinds has revised its Code Digest for 2017 to meet the needs of design personnel for a ready reference to

Still Have a Technical Question?

Our photonic engineering team can help you select the right connector or splitter for your network.

Ask Our Team